DOTCODE: Fix best_mask -> high_score prime test; manual mask

This commit is contained in:
gitlost 2021-01-22 18:07:59 +00:00
parent fb12fe4e79
commit f6bed3acb2
11 changed files with 872 additions and 195 deletions

View file

@ -138,7 +138,7 @@ static void usage(void) {
" --height=NUMBER Set height of symbol in multiples of X-dimension\n"
" -i, --input=FILE Read input data from FILE\n"
" --init Create reader initialisation/programming symbol\n"
" --mask=NUMBER Set masking pattern to use (QR/Han Xin)\n"
" --mask=NUMBER Set masking pattern to use (QR/Han Xin/DotCode)\n"
" --mirror Use batch data to determine filename\n"
" --mode=NUMBER Set encoding mode (MaxiCode/Composite)\n"
" --nobackground Remove background (PNG/SVG/EPS only)\n"
@ -904,7 +904,7 @@ int main(int argc, char **argv) {
fprintf(stderr, "Error 131: Invalid columns value\n");
return do_exit(1);
}
if ((val >= 1) && (val <= 67)) {
if ((val >= 1) && (val <= 108)) {
my_symbol->option_2 = val;
} else {
fprintf(stderr, "Warning 111: Number of columns out of range\n");