Add compliant height, using ZINT_COMPLIANT_HEIGHT flag for back-compatibility
Rename barcode funcs to same as BARCODE_XXX name library: barcode funcs array for dispatch, used for ZBarcode_ValidID() also general: change is_sane() comparison to nonzero from ZINT_ERROR_INVALID_OPTION MAILMARK: fuller error messages CODABAR: add option to show check character in HRT zint.h: use 0xNNNN for OR-able defines GUI: add guard descent height reset button, add Zint version to window title, static get_zint_version() method, use QStringLiteral (QSL shorthand), use SIGNAL(toggled()), add errtxt "popup" and status bar, add icons, add saveAs shortcut, add main menu, context menus and actions, add help, reset_view() -> reset_colours(), add copy to clipboard as EMF/GIF/PNG/TIF, lessen triggering of update_preview(), shorten names of getters/setters, simplify/shorten some update_preview() logic in switch, CODEONE disable structapp for Version S qzint.cpp: add on_errored signal, add missing getters, add test
This commit is contained in:
parent
206ae26d20
commit
72eac41c34
82 changed files with 5570 additions and 3774 deletions
|
@ -1863,8 +1863,9 @@ purposes. The American Blood Commission adopted Codabar in 1977 as the standard
|
|||
symbology for blood identification. Codabar can encode any length string
|
||||
starting and ending with the letters A-D and containing between these letters
|
||||
the numbers 0-9, dash (-), dollar ($), colon (:), slash (/), full stop (.) or
|
||||
plus (+). No check digit is generated by default, but a modulo-16 one can be
|
||||
added by setting option_2 = 1 or using --vers=1.
|
||||
plus (+). No check characater is generated by default, but a modulo-16 one can
|
||||
be added by setting option_2 = 1 or using --vers=1. To have the check character
|
||||
appear in the Human Readable Text, set option_2 = 2 or --vers=2.
|
||||
|
||||
6.1.10 Pharmacode
|
||||
-----------------
|
||||
|
@ -2054,7 +2055,8 @@ in Codablock-F symbols.
|
|||
Code 16K uses a Code 128 based system which can stack up to 16 rows in a block.
|
||||
This gives a maximum data capacity of 77 characters or 154 numerical digits and
|
||||
includes two modulo-107 check digits. Code 16K also supports extended ASCII
|
||||
character encoding in the same manner as Code 128.
|
||||
character encoding in the same manner as Code 128. GS1 data encoding is also
|
||||
supported.
|
||||
|
||||
6.2.4 PDF417 (ISO 15438)
|
||||
------------------------
|
||||
|
@ -3171,7 +3173,7 @@ international standards:
|
|||
|
||||
> BS EN 797:1996 Bar coding - Symbology specifications - 'EAN/UPC'
|
||||
> BS EN 798:1996 Bar coding - Symbology specifications - 'Codabar'
|
||||
> ISO/IEC 12323:2005 AIDC technologies - Symbology specifications - Code 16K
|
||||
> BS EN 12323:2005 AIDC technologies - Symbology specifications - Code 16K
|
||||
> ISO/IEC 15417:2007 Information technology - Automatic identification and data
|
||||
capture techniques - Code 128 bar code symbology specification
|
||||
> ISO/IEC 15438:2015 Information technology - Automatic identification and data
|
||||
|
|