mirror of
https://git.code.sf.net/p/zint/code
synced 2025-05-09 13:41:59 -04:00
GRIDMATRIX: default char set is GB 2312 only, not Latin-1 with GB 2312 alt
HANXIN/QRCODE: use Hanzi/Kanji modes when compatible ECIs given manual: one true source now manual.pmd from which manual.txt is generated CLI: man page moved from frontend/zint.1.gz to docs/zint.1.gz, now generated from docs/zint.1.pmd add README.linux to root dir
This commit is contained in:
parent
9aae557cdc
commit
719613d4c3
160 changed files with 18144 additions and 2674 deletions
|
@ -510,6 +510,7 @@ static int gm_encode(unsigned int ddata[], const int length, char binary[], cons
|
|||
glyph = (0x60 * (c1 - 0xb0 + 9)) + (c2 - 0xa0);
|
||||
}
|
||||
done = 1; /* GB 2312 always within above ranges */
|
||||
/* Note not using the unallocated glyphs 7776 to 8191 mentioned in AIMD014 section 6.3.1.2 */
|
||||
}
|
||||
if (!(done)) {
|
||||
if (sp != (length - 1)) {
|
||||
|
@ -1055,7 +1056,7 @@ INTERNAL int gridmatrix(struct zint_symbol *symbol, struct zint_seg segs[], cons
|
|||
char *grid;
|
||||
#endif
|
||||
|
||||
segs_cpy(segs, seg_count, local_segs); /* Shallow copy (needed to set default ECIs & protect lengths) */
|
||||
segs_cpy(symbol, segs, seg_count, local_segs); /* Shallow copy (needed to set default ECIs & protect lengths) */
|
||||
|
||||
/* If ZINT_FULL_MULTIBYTE set use Hanzi mode in DATA_MODE or for non-GB 2312 in UNICODE_MODE */
|
||||
full_multibyte = (symbol->option_3 & 0xFF) == ZINT_FULL_MULTIBYTE;
|
||||
|
@ -1066,13 +1067,13 @@ INTERNAL int gridmatrix(struct zint_symbol *symbol, struct zint_seg segs[], cons
|
|||
unsigned int *dd = ddata;
|
||||
for (i = 0; i < seg_count; i++) {
|
||||
int done = 0;
|
||||
if (local_segs[i].eci != 29 || seg_count > 1) { /* Unless ECI 29 (GB 2312) or have multiple segments */
|
||||
/* Try other conversions (ECI 0 defaults to ISO/IEC 8859-1) */
|
||||
if (local_segs[i].eci != 0 && local_segs[i].eci != 29) { /* Unless default or ECI 29 (GB 2312) */
|
||||
/* Try other conversions */
|
||||
error_number = gb2312_utf8_to_eci(local_segs[i].eci, local_segs[i].source, &local_segs[i].length,
|
||||
dd, full_multibyte);
|
||||
if (error_number == 0) {
|
||||
done = 1;
|
||||
} else if (local_segs[i].eci || seg_count > 1) {
|
||||
} else {
|
||||
sprintf(symbol->errtxt, "535: Invalid character in input data for ECI %d", local_segs[i].eci);
|
||||
return error_number;
|
||||
}
|
||||
|
@ -1083,10 +1084,6 @@ INTERNAL int gridmatrix(struct zint_symbol *symbol, struct zint_seg segs[], cons
|
|||
if (error_number != 0) {
|
||||
return error_number;
|
||||
}
|
||||
if (local_segs[i].eci != 29) {
|
||||
strcpy(symbol->errtxt, "540: Converted to GB 2312 but no ECI specified");
|
||||
warn_number = ZINT_WARN_NONCOMPLIANT;
|
||||
}
|
||||
}
|
||||
dd += local_segs[i].length;
|
||||
}
|
||||
|
|
Loading…