mirror of
https://git.code.sf.net/p/zint/code
synced 2025-05-27 13:34:19 -04:00
- Add new symbologies BARCODE_EAN8
, BARCODE_EAN_2ADDON
,
`BARCODE_EAN_5ADDON`, `BARCODE_EAN13`, `BARCODE_EAN8_CC` and `BARCODE_EAN13_CC` as replacements for `BARCODE_EANX`, `BARCODE_EANX_CHK` and `BARCODE_EANX_CC` and use in CLI/GUI (`BARCODE_EANX` etc. marked as legacy) - For EAN/UPC accept space as alternative add-on separator to '+', and accept GTIN-13 format with & without 2-digit or 5-digit add-on (no separator) - Buffer length of member `errtxt` in `zint_symbol` extended 100 -> 160 (will be sufficient for eventual translation and gs1-syntax-dictionary errors hopefully) - UPC-E: warn if first digit of 7 (or 8 if check digit given) not '0' or '1' - manual: update for new EAN symbologies and mention EANX now legacy but still supported
This commit is contained in:
parent
9265abd9e1
commit
3592edd64e
51 changed files with 6995 additions and 4949 deletions
|
@ -910,7 +910,8 @@ namespace Zint {
|
|||
return true;
|
||||
break;
|
||||
default:
|
||||
return symbology >= BARCODE_EANX_CC && symbology <= BARCODE_DBAR_EXPSTK_CC;
|
||||
return (symbology >= BARCODE_EANX_CC && symbology <= BARCODE_DBAR_EXPSTK_CC)
|
||||
|| symbology == BARCODE_EAN8_CC || symbology == BARCODE_EAN13_CC;
|
||||
break;
|
||||
}
|
||||
}
|
||||
|
|
Loading…
Add table