mirror of
https://git.code.sf.net/p/zint/code
synced 2025-05-28 14:04:19 -04:00
Allow explicit ECI 3
Setting ECI to 3 now causes Zint to include ECI 3 in symbol, and allows entry of data formatted in ISO 8859_1 Fixes #127 requested by Harald Oehlmann
This commit is contained in:
parent
ff2ceea361
commit
15ae99ee11
9 changed files with 1362 additions and 1362 deletions
|
@ -166,7 +166,7 @@ static void qr_binary(int datastream[], const int version, const int target_binl
|
|||
strcat(binary, "0101"); /* FNC1 */
|
||||
}
|
||||
|
||||
if (eci != 3) {
|
||||
if (eci != 0) {
|
||||
strcat(binary, "0111"); /* ECI (Table 4) */
|
||||
if (eci <= 127) {
|
||||
bin_append(eci, 8, binary); /* 000000 to 000127 */
|
||||
|
@ -1338,7 +1338,7 @@ static int getBinaryLength(const int version,char inputMode[],const int inputDat
|
|||
count += 4;
|
||||
}
|
||||
|
||||
if (eci != 3) {
|
||||
if (eci != 0) {
|
||||
count += 12;
|
||||
}
|
||||
|
||||
|
@ -1425,7 +1425,7 @@ int qr_code(struct zint_symbol *symbol, const unsigned char source[], size_t len
|
|||
|
||||
gs1 = (symbol->input_mode == GS1_MODE);
|
||||
|
||||
if ((symbol->input_mode == DATA_MODE) || (symbol->eci != 3)) {
|
||||
if ((symbol->input_mode == DATA_MODE) || (symbol->eci != 0)) {
|
||||
for (i = 0; i < length; i++) {
|
||||
jisdata[i] = (int) source[i];
|
||||
}
|
||||
|
|
Loading…